{"id":442,"date":"2023-02-22T14:48:38","date_gmt":"2023-02-22T14:48:38","guid":{"rendered":"https:\/\/omnianaval.com\/?p=442"},"modified":"2024-11-14T18:18:43","modified_gmt":"2024-11-14T18:18:43","slug":"tr19-grease-standards-insight-and-updates","status":"publish","type":"post","link":"https:\/\/omnianaval.com\/index.php\/2023\/02\/22\/tr19-grease-standards-insight-and-updates\/","title":{"rendered":"TR19\u00ae Grease Standards \u2013 Insight and Updates"},"content":{"rendered":"\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\">The risk of fire ventilation from build up of grease deposits in kitchen extract systems has resulted in an ever more stringent level of ventilation system cleanliness being required.<\/p>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\">BESA first published TR\/17 in 1998 in order to give guidance to good practice and to establish standards for testing, cleaning and verification of the internal cleanliness of ventilation systems.<\/p>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\">The guide was re-published and renumbered&nbsp;TR\/19 and incorporates the reference to the new British and European Standard BS EN 15780 Cleanliness of Ventilation Systems introduced in 2011.&nbsp;<\/p>\n\n\n\n<h2 class=\"has-large-font-size wp-block-heading\">Updates to <strong>TR19\u00ae<\/strong> Grease specifications<\/h2>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\">Recent changes were made to highlight the current best practice for ensuring that kitchen extract systems are maintained to minimise the risk of fire associated with grease accumulation.&nbsp;<\/p>\n\n\n\n<p class=\"has-secondary-color has-text-color has-quicksand-font-family has-medium-font-size wp-block-paragraph\" style=\"font-style:normal;font-weight:400\">Kitchen extract systems are not covered by <strong>BS EN 15780<\/strong>. In this Third Edition, Section 7 has been withdrawn and has been superseded by TR19 Grease, a new, stand-alone specification for Fire Risk Management of Grease Accumulation within Kitchen Extraction Systems.\u00a0<\/p>\n\n\n\n<h2 class=\"has-large-font-size wp-block-heading\"><strong>Latest TR19\u00ae Grease updates<\/strong><\/h2>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\"><strong>TR19\u00ae Grease<\/strong> is a new specification, issued in July 2019 by The BESA (Building Engineering Services Association), which specifically focuses on the fire risk management of grease accumulation within kitchen extraction systems.\u00a0 Changes to the TR19 guidelines contains updated information regarding the industry standards for managing grease levels within commercial kitchen ventilation systems. <\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"361\" src=\"https:\/\/omnianaval.com\/wp-content\/uploads\/2023\/02\/cleaning-kitchen-grease.jpg\" alt=\"\" class=\"wp-image-451 size-full\" srcset=\"https:\/\/omnianaval.com\/wp-content\/uploads\/2023\/02\/cleaning-kitchen-grease.jpg 640w, https:\/\/omnianaval.com\/wp-content\/uploads\/2023\/02\/cleaning-kitchen-grease-300x169.jpg 300w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"has-quicksand-font-family has-large-font-size wp-block-paragraph\"><em>&#8220;A key update is that a business must use an accredited service provider in order to be TR19 compliant.\u00a0<\/em>&#8220;<\/p>\n<\/div><\/div>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\">It expands upon and replaces what had been one section of the second edition of the TR19 regulations that provided guidance on duct and kitchen extract system cleaning. Rather than simply providing best[1]practice guidelines, the new <strong>TR19\u00ae Grease <\/strong>standalone document is a specification in its own right which must be followed by contractors operating in the sector under this specification.<\/p>\n\n\n\n<h2 class=\"has-medium-font-size wp-block-heading\"><strong>Why TR19\u00ae Grease?<\/strong><\/h2>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\">The risk of fire from the build up of grease deposits in kitchen extract systems and the expectations of building occupiers and legislators has resulted in an ever more stringent level of ventilation system cleanliness being required, and TR19\u00ae Grease details precisely what is required to manage that risk.<\/p>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\">Contractors carrying out extract cleaning work must be members of the Building Engineering Services Competence Assessment (BESCA) Ventilation Hygiene Elite (VHE) Scheme if they wish to certify their work as TR19\u00ae Grease &nbsp;&nbsp;Members of the VHE Scheme must also abide by the BESCA Code of Conduct &nbsp;&nbsp;<\/p>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\"><strong>TR19\u00ae Grease<\/strong> introduces minimum competency levels for technicians carrying out and signing off on-site kitchen extract cleaning. Technicians must now have completed specialist training and hold the BESA Grease Hygiene Technician (GHT) qualification. \u00a0\u00a0<\/p>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\">Every time a kitchen extract clean is carried out the contractor must register on the BESCA VHE portal where and when the clean was carried out and whether the system was fully or partially cleaned.<\/p>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\">A certificate will then be produced to provide evidence of the compliance of the clean (a small fee is charged by BESCA for each certificate). &nbsp;&nbsp;<\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 31%\"><div class=\"wp-block-media-text__content\">\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\">Cleaning frequencies must be regularly reviewed to ensure that grease can be controlled at safe levels. Grease levels must be controlled so as to not exceed a mean average of 200 microns between scheduled cleans. How will the new Ventilation Hygiene Elite scheme ensure that best practice is observed? \u00a0\u00a0<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"257\" height=\"196\" src=\"https:\/\/omnianaval.com\/wp-content\/uploads\/2023\/02\/duct-with-grease.jpg\" alt=\"\" class=\"wp-image-447 size-full\"\/><\/figure><\/div>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\">Cleaning frequencies must be regularly reviewed to ensure that grease can be controlled at safe levels. Grease levels must be controlled so as to not exceed a mean average of 200 microns between scheduled cleans. How will the new Ventilation Hygiene Elite scheme ensure that best practice is observed? &nbsp;&nbsp;<\/p>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\">BESCA will monitor and audit the compliance of VHE members, both with its code of conduct and with the TR19\u00ae Grease specification &nbsp;<\/p>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\">&nbsp;VHE members will be audited at regular intervals by BESCA auditors, who will review a selection of completed post-clean reports for compliance auditing purposes. &nbsp;&nbsp;<\/p>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\">BESCA will be able to revoke or reject the membership of contractors who are considered to be in breach of the VHE Scheme&#8217;s requirements or code of conduct<\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\" style=\"grid-template-columns:38% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"680\" src=\"https:\/\/omnianaval.com\/wp-content\/uploads\/2023\/02\/cleaned.jpg\" alt=\"\" class=\"wp-image-449 size-full\" srcset=\"https:\/\/omnianaval.com\/wp-content\/uploads\/2023\/02\/cleaned.jpg 1000w, https:\/\/omnianaval.com\/wp-content\/uploads\/2023\/02\/cleaned-300x204.jpg 300w, https:\/\/omnianaval.com\/wp-content\/uploads\/2023\/02\/cleaned-768x522.jpg 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"has-text-align-center has-quicksand-font-family has-large-font-size wp-block-paragraph\">To mitigate risk and ensure compliance, call the professionals for effective and safe\u00a0kitchen ventilation cleaning.<\/p>\n<\/div><\/div>\n\n\n\n<p class=\"has-quicksand-font-family has-medium-font-size wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button aligncenter\"><a class=\"wp-block-button__link has-tertiary-background-color has-background wp-element-button\" href=\"https:\/\/omnianaval.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">Get a Free Quote<\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The risk of fire ventilation from build up of grease deposits in kitchen extract systems has resulted in an ever more stringent level of ventilation system cleanliness being required. BESA first published TR\/17 in 1998 in order to give guidance to good practice and to establish standards for testing, cleaning and verification of the internal [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":446,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[7,25],"tags":[12,11,28,10],"class_list":["post-442","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-kes-hygiene","category-news","tag-greasecleaning","tag-kitchenexctracthygiene","tag-news","tag-tr19grease"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/omnianaval.com\/index.php\/wp-json\/wp\/v2\/posts\/442","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/omnianaval.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/omnianaval.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/omnianaval.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/omnianaval.com\/index.php\/wp-json\/wp\/v2\/comments?post=442"}],"version-history":[{"count":5,"href":"https:\/\/omnianaval.com\/index.php\/wp-json\/wp\/v2\/posts\/442\/revisions"}],"predecessor-version":[{"id":452,"href":"https:\/\/omnianaval.com\/index.php\/wp-json\/wp\/v2\/posts\/442\/revisions\/452"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/omnianaval.com\/index.php\/wp-json\/wp\/v2\/media\/446"}],"wp:attachment":[{"href":"https:\/\/omnianaval.com\/index.php\/wp-json\/wp\/v2\/media?parent=442"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/omnianaval.com\/index.php\/wp-json\/wp\/v2\/categories?post=442"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/omnianaval.com\/index.php\/wp-json\/wp\/v2\/tags?post=442"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}